RS412

초전 적외선 센서

PROD Model: RS412

Window Size: 3*4mm

Output Signal:Digital signal output

Sensing Distance: 10M (lens SB-F-02)

See lens selection for different distances

Sensing Angle: 120° (horizontal direction)

Working Voltage: 1.6-5.5V

Static Power Consumption: <10uA

Recommended Supporting IC: Customized MCU

RS412 Описание продукта

It is a low power pyroelectric infrared sensor(PIR) for motion detection . Using the MCU for communication,when the RS412 performs continuous motion sensing,the MCU does not need to be activated, it only activates the external MCU when motion is detected. Motion detection results are sent out via the output interrupt signal.The algorithm for motion detection is programmable and can be changed by external MCU configuration, The PIR signal is converted into a 14-bit digital value on the chip, and then enters the motion algorithm detection unit. All signal processing is digital and supports motion detection result output and raw data output.

RS412 Характеристики продукта

Power supply voltage range 1.6~5.5V

Programmable detection standard and working mode

Digital signal processing

Ultra low power consumption

Power supply voltage measurement

Temperature measurement

Fast and stable power-on

RS412 Технические данные

Technical data 

1.Absolute Maximum Ratings 

Description

Conditions

Symbol

Min

Typical

Max

Unit

VDD voltage

25℃

VDD

-0.3

5.5

V

25℃

Analog pin voltage

25℃


-0.3

VDD+0.3

V

25℃

Digital pin voltage

25℃


-0.3

VDD+0.3

V

25℃

Storage temperature

VDD


-30

80

℃


2.Operating Conditions ( TAMB = +25℃  Typical VDD=3V)

Description

Conditions

Symbol

Min

Typical

Max

Unit

Operating temperature

Operating temperature range



-20


+70

℃

Operating Voltage

Supply voltage


VDD

1.6


5.5

V

Supply current

Supply current

VDD=3V

IDD


8

11

µA

Detective Wavelength

Detective Wavelength


λ

5


14

μm

Input parameter SERIN

Input low voltage


VIL



0.2

VDD

Input high voltage


VIH

0.8



VDD

Input Current

VSS<VIN<VDD

IIN

-1


1

µA

Digital clock low time


tL

200



ns

Digital clock high time


tH

200



ns

Data Bit Write Time


tBW

2/FCLK


5/FCLK

µs

Write timeout


tWL

16/FCLK



µs

Data input and output pins INT/DOCI

Input low voltage


VIL



0.2

VDD

Input high voltage


VIH

0.8



VDD

Output current high

VOL>(VDD-1V)

IOH



-200

µA

Output current low

VOL<1V

IOL

200



µA

Input capacitance




5


pF

Force read setup time


TFR

2/FCLK




Interrupt clear time


tCL

2/FCLK




Digital clock low time


tL

200


tRA

ns

Digital clock high time


tH

200



ns

Read timeout


tRA

4/F



µs

Supply voltage measurement

Resolution



590

650

720

µV/count

ADC output range



2^13

2^14-511


Counts

Temperature measurement (requires single point calibration)

Resolution




80


Counts/K

ADC output range



511


2^14-511

Counts

Value at 300K



6700

8200

9900

Counts

Oscillator and Filter

Filter cutoff frequency



FCLK * 1.41 / 2048 / PI

Hz

HPF cutoff frequency



FCLK /16 * 1.41 / 2048 / PI

Hz

On-chip oscillator frequency


FOSC

56

64

74

kHz

System clock


FCLK


FOSC/2



Precautions:

1. The factory parameters of the sensor are obtained after a few minutes of stabilization time under the standard black body and stable test environment.

2. The sensor needs to be used with a Fresnel lens to achieve the ideal sensing angle and sensing distance.

3. The sensing distance of the sensor is directly related to the ambient temperature and humidity, the temperature and moving direction of the acquisition target, the Fresnel lens, and the magnification setting. Please consider it comprehensively when using it.

4. The sensitive components inside the sensor are relatively thin and brittle. Please handle it with care when using it. High-frequency vibration or drop impact may cause the sensitive components to break.

5. The sensor window is a silicon-based semiconductor special material vacuum-coated filter lens. Please do not touch it directly with your hands or hard objects.

6. Selection of sensor window: analog in-line dual-element products: S: 3*4mm, B: 3.8*5mm, digital in-line dual-element products: S: 3*4mm, L: 3.8*5mm, M: 4.2*5.2 mm, in-line quaternary products: X: 4*4mm, Q: 4.9*4.9mm. For details, please communicate with the salesperson.

7. Sensor lead length selection: the default default is 13.5mm. If you have other needs, you can consult the salesman for details. Customized lead length is supported.

8. For other details of the sensor, please refer to the product manual.

RS412 Документ со спецификациями

Access detailed technical information, configuration guides, and solutions notes to support your evaluation and implementation of the RS412 Series.

  • RS412 Техническая спецификация

    Исчерпывающие технические характеристики и подробные справочные данные по модулям и компонентам.

    Скачать
  • RS412 Распиновка

    Стандартная распиновка, определение интерфейса и назначение сигнальных контактов для обеспечения надежного соединения.

    Скачать
  • RS412 Принципиальная схема

    Полная схема электрических соединений, принципиальная схема применения и типовая схема подключения — для использования при проектировании.

    Скачать
Получите образцы RS412 уже сегодня

Свяжитесь с нашим отделом продаж, чтобы получить образцы, техническую поддержку и узнать о выгодных ценах. Мы предлагаем индивидуальные решения, адаптированные к вашим конкретным требованиям.

Запросить образцы
Отправить сообщение

Оставьте свои контактные данные, и мы предоставим вам профессиональные услуги.

️
Напрямую от производителя

Избавьтесь от наценок — приобретайте оригинальные PIR-датчики напрямую с нашего предприятия.

Профессиональная техническая поддержка

Наши инженеры обеспечивают полное сопровождение — от выбора до интеграции.

Гибкий минимальный объем заказа

Будь то выпуск опытной партии или серийное производство — мы поможем вам в любом случае.

Глобальные стандарты

Полностью соответствует требованиям CE, RoHS и REACH для международных рынков.